Page 8
Pyramid Universal Dome Interface Installation Manual
CONNECTING AND CONFIGURING THE UDI
Pyramid Data Connector - This three-way terminal is used to connect the UDI to the Pyramid network. This can
be either a RS485 or FTT10 network depending on the UDI variant in use. Connect the UDI to the network using
pins 2 and 3 (labelled + and - to indicate polarity), and connect the cable screen to ground on pin 1 (labelled
).
A good connection to the local ground plane is also required, and this should also be made to the Pyramid
Data Connector on pin 1 (labelled
). This is necessary to ensure compliance with ESD directives and to
protect against transients on any connections.
CONNECTING A BAXALL PRO DOME CAMERA
To connect a Baxall Pro Dome camera to the UDI, follow the steps below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Remove the dome assembly from the base. Connect the wire from the from the UDIs Dome Data Connector to the
nine-pin connector on the underside of the dome assembly:
Connecting and configuring a Baxall Pro Dome
2. Use the three rotary switches, labelled 1, 10 and 100, to set the dome address to 1. To do this, set rotary switch 1
to 1, and rotary switches 10 and 100 to 0, as shown in the diagram above.
3. Reconnect the dome assembly to the base.
CONNECTING AN ULTRAK DOME CAMERA
To connect an Ultrak dome camera to the UDI, follow the steps below:
When connecting the UDI to a dome, reference should also be made to documentation provided with the dome.
1. Remove the dome camera from its housing.
2. On the base inside the housing, connect the eight-way terminal block labelled TB1 to the wire from the UDIs Dome
Data Connector. Use the diagram below as a guide:
WIRES FROM DOME DATA CONNECTOR ON UDI:
FROM GROUND TERMINAL
FROM + TERMINAL
FROM - TERMINAL
-
+
Connecting an Ultrak Dome to the UDI
Comentários a estes Manuais